PRODUCTS
Products
Fire-resistant Telephone and Instrumentation Cable with Individual Shield
Category:
Key words:
Fire-resistant Telephone and Instrumentation Cable with Individual Shield
our products are also exported to clients in such countries and regions as USA, Germany, UK, Malaysia, Switzerland, Japan, Australia, Korea, Canada, Russia, Netherland, UAE etc. and win good feedbacks from our customers.
PRODUCT DETAIL
150/250V FR-TTPYC-S, FR-FA-TTPYC-S
150/250V FR-TTPYCY-S, FR-FA-TTPYCY-S
Standards applied
IEC 60092-350, 376 Construction
IEC 60092-360 Insulation & Sheath
IEC 60332-1 Flame retardant
IEC 60332-3-22 Flame retardant (FA type)
IEC 60331 Fire resistant
Operating temperature: 90℃
Construction
| Components | Code | Material/Description |
| Conductor | TT | Stranded tinned annealed copper wire |
| A suitable tape may be applied on the conductor | ||
| Fire-proof Layer | FR- | Mica/glass tape |
| Insulation | P | Ethylene Propylene Rubber (EPR) |
| Individual Shield | -S | Aluminium backed polyester tape with a copper drain wire |
| Cabling | Flame retardant & non-hygroscopic fillers may be used | |
| Suitable tape(s) may be applied on the cabled core | ||
| Sheath | Y | Polyvinyl Chloride (PVC) |
| Armor | C | Galvanized steel wire braid |
| Paint | White paint shall be uniformly painted on the braid | |
| Not necessary for Y (protective cover) type | ||
| Protective Cover | Y | Polyvinyl Chloride (PVC) |
| Type | Description | Voltage |
| FR-TTPYC-S | EPR insulated PVC sheathed and steel wire braided fire resistant instrumentation cable with Individual shield | 150/250V |
| FR-TTPYCY-S | EPR insulated PVC sheathed steel wire braided and PVC protective covered fire resistant instrumentation cable with Individual shield | 150/250V |
| FR-FA-TTPYC-S | EPR insulated PVC sheathed and steel wire braided flame retardant and fire resistant instrumentation cable with Individual shield | 150/250V |
| FR-FA-TTPYCY-S | EPR insulated PVC sheathed steel wire braided and PVC protective covered flame retardant and fire resistant instrumentation cable with Individual shield | 150/250V |
| Specifications | |||
| FR-TTPYC-4S | FR-FA-TTPYC-4S | FR-TTPYCY-4S | FR-FA-TTPYCY-4S |
| FR-TTPYC-7S | FR-FA-TTPYC-7S | FR-TTPYCY-7S | FR-FA-TTPYCY-7S |
| FR-TTPYC-10S | FR-FA-TTPYC-10S | FR-TTPYCY-10S | FR-FA-TTPYCY-10S |
| FR-TTPYC-14S | FR-FA-TTPYC-14S | FR-TTPYCY-14S | FR-FA-TTPYCY-14S |
| FR-TTPYC-19S | FR-FA-TTPYC-19S | FR-TTPYCY-19S | FR-FA-TTPYCY-19S |
| FR-TTPYC-24S | FR-FA-TTPYC-24S | FR-TTPYCY-24S | FR-FA-TTPYCY-24S |
| FR-TTPYC-30S | FR-FA-TTPYC-30S | FR-TTPYCY-30S | FR-FA-TTPYCY-30S |
| FR-TTPYC-37S | FR-FA-TTPYC-37S | FR-TTPYCY-37S | FR-FA-TTPYCY-37S |
| FR-TTPYC-48S | FR-FA-TTPYC-48S | FR-TTPYCY-48S | FR-FA-TTPYCY-48S |